GallonGaugeGallons, first-hour rating and GPM — the three numbers that decide it.

Venting & Install

Clearances, venting, expansion tanks and the code items that add to a swap.

1 article

Venting a direct-vent gas water heater with a 20 ft run

direct-vent gas (sealed combustion), 20 ft of vent
concentric or two-pipe kit supplied by the manufacturer
inside the 40 ft this category typically allows
Vent materialconcentric or two-pipe kit supplied by the manufacturer
Vent size2″ or 3″
Length limit40 ft equivalent
Vent run20ft
Combustion airtaken from outdoors through the second pipe — nothing is drawn from the room
Heater typethe right answer for a tight closet or a bedroom-adjacent spacedirect-vent gas (sealed combustion)

Notes

  • "Can I vent it with PVC" depends entirely on the category, and getting it wrong is not a code technicality. direct-vent gas (sealed combustion) vents with concentric or two-pipe kit supplied by the manufacturer. Plastic on a Category I heater softens and fails at exhaust temperatures it was never rated for; metal on a condensing heater is eaten by acidic condensate within a few years. The appliance's own manual overrides every general rule, including this page.
  • 20 ft is comfortably inside the limit for this category, but measure it as equivalent length: each 90° elbow adds roughly 5 ft and each 45° about half that. A run that measures 20 ft on the tape with four elbows is closer to 40 ft to the appliance.
  • Combustion air is the part that gets skipped. taken from outdoors through the second pipe — nothing is drawn from the room. A confined space — a closet, a small utility room — needs either 50 ft³ of volume per 1,000 BTU/hr or two permanent openings, one high and one low, each 1 in² per 1,000 BTU/hr. Sealing up a draughty basement is a common way to make a heater that worked for twenty years start backdrafting.
  • A drain pan with a line to somewhere is worth its cost the first time. Tanks fail by leaking, not by bursting, and they do it while nobody is home. Where the heater sits above finished space, most codes now require the pan and the drain; where they do not, install it anyway.
  • Have the draft checked after any change to the house. A new bathroom fan, a kitchen hood, or a tighter set of windows can pull enough air to reverse a Category I vent. A smoke test at the draft hood takes a minute and is the difference between a working flue and carbon monoxide in the hallway.

Open the full page for this calculation

Water heater venting

42 calculations · browse all