GallonGaugeGallons, first-hour rating and GPM — the three numbers that decide it.

Venting a condensing gas water heater with a 60 ft run

condensing gas (Category IV), 60 ft of vent
PVC, CPVC or polypropylene, plus a condensate drain
inside the 100 ft this category typically allows
Vent materialPVC, CPVC or polypropylene, plus a condensate drain
Vent size2″ or 3″
Length limit100 ft equivalent
Vent run60ft
Combustion airusually sealed combustion, air taken from outdoors
Heater typeexhaust leaves near room temperature, so plastic is not only allowed but requiredcondensing gas (Category IV)

Notes

  • "Can I vent it with PVC" depends entirely on the category, and getting it wrong is not a code technicality. condensing gas (Category IV) vents with PVC, CPVC or polypropylene, plus a condensate drain. Plastic on a Category I heater softens and fails at exhaust temperatures it was never rated for; metal on a condensing heater is eaten by acidic condensate within a few years. The appliance's own manual overrides every general rule, including this page.
  • 60 ft is comfortably inside the limit for this category, but measure it as equivalent length: each 90° elbow adds roughly 5 ft and each 45° about half that. A run that measures 60 ft on the tape with four elbows is closer to 80 ft to the appliance.
  • Combustion air is the part that gets skipped. usually sealed combustion, air taken from outdoors. A confined space — a closet, a small utility room — needs either 50 ft³ of volume per 1,000 BTU/hr or two permanent openings, one high and one low, each 1 in² per 1,000 BTU/hr. Sealing up a draughty basement is a common way to make a heater that worked for twenty years start backdrafting.
  • A drain pan with a line to somewhere is worth its cost the first time. Tanks fail by leaking, not by bursting, and they do it while nobody is home. Where the heater sits above finished space, most codes now require the pan and the drain; where they do not, install it anyway.
  • Have the draft checked after any change to the house. A new bathroom fan, a kitchen hood, or a tighter set of windows can pull enough air to reverse a Category I vent. A smoke test at the draft hood takes a minute and is the difference between a working flue and carbon monoxide in the hallway.

PVC, CPVC or polypropylene, plus a condensate drain

That is the material a condensing gas water heater vents with, at 2″ or 3″. Getting it wrong is not a paperwork problem: plastic on a hot-exhaust appliance softens and fails, and metal on a condensing appliance is eaten through by acidic condensate.

Combustion air

usually sealed combustion, air taken from outdoors

A confined space needs either 50 ft³ of volume per 1,000 BTU/hr, or two permanent openings — one high, one low — each sized at 1 in² per 1,000 BTU/hr. Sealing up a draughty basement is a well-documented way to make a heater that vented correctly for twenty years start spilling exhaust into the room.

Where the manual beats every general rule

Vent length limits, permitted materials and termination clearances are specific to the model. This page tells you which family of answers to expect; the appliance's installation manual is the authority, and the inspector will read it rather than this.

Nearby sizes

Read more