Venting a direct-vent gas water heater with a 60 ft run

direct-vent gas (sealed combustion), 60 ft of vent
concentric or two-pipe kit supplied by the manufacturer
over the 40 ft this category typically allows — check the model's own table
Vent materialconcentric or two-pipe kit supplied by the manufacturer
Vent size2″ or 3″
Length limit40 ft equivalent
Vent run60ft
Combustion airtaken from outdoors through the second pipe — nothing is drawn from the room
Heater typethe right answer for a tight closet or a bedroom-adjacent spacedirect-vent gas (sealed combustion)

Notes

  • "Can I vent it with PVC" depends entirely on the category, and getting it wrong is not a code technicality. direct-vent gas (sealed combustion) vents with concentric or two-pipe kit supplied by the manufacturer. Plastic on a Category I heater softens and fails at exhaust temperatures it was never rated for; metal on a condensing heater is eaten by acidic condensate within a few years. The appliance's own manual overrides every general rule, including this page.
  • 60 ft is past the 40 ft this category usually allows, and equivalent length is worse than measured length — every elbow counts for several feet. Some models permit longer runs with a larger pipe diameter; the manufacturer's vent table is the only authority. Do not assume the extra run "probably works".
  • Combustion air is the part that gets skipped. taken from outdoors through the second pipe — nothing is drawn from the room. A confined space — a closet, a small utility room — needs either 50 ft³ of volume per 1,000 BTU/hr or two permanent openings, one high and one low, each 1 in² per 1,000 BTU/hr. Sealing up a draughty basement is a common way to make a heater that worked for twenty years start backdrafting.
  • A drain pan with a line to somewhere is worth its cost the first time. Tanks fail by leaking, not by bursting, and they do it while nobody is home. Where the heater sits above finished space, most codes now require the pan and the drain; where they do not, install it anyway.
  • Have the draft checked after any change to the house. A new bathroom fan, a kitchen hood, or a tighter set of windows can pull enough air to reverse a Category I vent. A smoke test at the draft hood takes a minute and is the difference between a working flue and carbon monoxide in the hallway.

concentric or two-pipe kit supplied by the manufacturer

That is the material a direct-vent gas water heater vents with, at 2″ or 3″. Getting it wrong is not a paperwork problem: plastic on a hot-exhaust appliance softens and fails, and metal on a condensing appliance is eaten through by acidic condensate.

Combustion air

taken from outdoors through the second pipe — nothing is drawn from the room

A confined space needs either 50 ft³ of volume per 1,000 BTU/hr, or two permanent openings — one high, one low — each sized at 1 in² per 1,000 BTU/hr. Sealing up a draughty basement is a well-documented way to make a heater that vented correctly for twenty years start spilling exhaust into the room.

Where the manual beats every general rule

Vent length limits, permitted materials and termination clearances are specific to the model. This page tells you which family of answers to expect; the appliance's installation manual is the authority, and the inspector will read it rather than this.